Skip to content

How it works

Your hardware. Your logic. Your screen.

AquaLoad is a Node-RED palette, running on Victron GX devices or Home Assistant. Any service that runs Node-RED.

Hardware

Geyserwise, Geyserwala Connect, Shelly, Elon Smart (by Kwikot), or a Victron GX relay. Same model per load. Geyser, heat pump, pool or pump: the hardware stays yours.

What makes it unique

Not only a geyser.

AquaLoad is a Node-RED palette. It heats water when you need it. The Coordinator also runs several other loads on the same site.

  • 3kWGeyser 1
  • 2kWGeyser 2
  • 1.5kWHeat pump
  • 1kWPool
  • 500WOther

Coordinator

Capacity
15kW
Other loads
2kW
Total loads
2kW
  • Watches site consumption
  • Holds a max load
  • Starts in your priority

Who may run

Base load

  • 2kW other loads

The rest wait.

Where it stands

Ready on Victron and Home Assistant.

AquaLoad is a Node-RED palette, running on Victron GX devices or Home Assistant. Any service that runs Node-RED. AquaBrik and a remote console come later.

Start process

$75. We install and test it.

A short loop: chat, order, install, run. Support stays in that loop.

  1. 01

    Chat

    A quick chat before we start. We check the site and the hardware.

  2. 02

    Order

    PayPal, or EFT for South African users only (R1,100 incl VAT).

  3. 03

    Install + Test

    Share access. Blue Dynamics installs the palette and tests it remotely.

  4. 04

    Run

    You use the screen you already open. Off, On or Auto. No new app.

05

Support

Need a hand later? We come back to Chat. Still here after handover.

Support loops back to Chat. Not a one-way handover.

  • Software

    The AquaLoad Node-RED palette. We configure it remotely on your Victron GX or Home Assistant.

  • Hardware

    Consult with us on the best hardware option for your application.

The palette

What AquaLoad actually does.

  • Four ways to heat

    Boost, solar dump, timers and min temp. Happy-Wife-Happy-Life sits on that min-temp floor, so the tank does not sit cold overnight.

  • Hardware you already own

    Geyserwise, Geyserwala Connect, Shelly, Elon Smart (by Kwikot) and Victron relays. Same logic per load.

  • The screen you already open

    Victron, Home Assistant or Remote Console. Off, On or Auto, and a live reason the load is on.

  • One Coordinator

    Several loads in priority. It watches Victron consumption, respects max load, sheds overload and uses solar when there is room.

  • Local, not cloud

    The palette runs on the box. If the internet drops, it still runs. If Node-RED stops, loads stay as they were.

  • Installed, not downloaded

    Blue Dynamics puts it on your Node-RED, tests the flows and hands over. Not a file you import yourself.